An aircon that runs but doesn’t cool usually has one of three problems: the wrong mode or set temperature, a clogged filter, or a blocked outdoor unit. All three take minutes to check. If it’s still blowing warm air after that, you’re likely looking at a refrigerant or compressor fault, and that needs a licensed technician.

Key Takeaways

  • Cooling can make up around 40% of a summer energy bill in the average WA home (WA Government).
  • Daikin recommends cleaning indoor unit filters every two weeks.
  • Low refrigerant means a leak, and only a licensed technician can repair it.

What Causes an Aircon to Stop Cooling?

Most cooling problems start with settings or airflow, not broken parts. Mitsubishi Electric’s troubleshooting advice is to check the set temperature and the mode first, then the filters and vents. It’s worth getting right: the WA Government’s summer energy guide says cooling can make up around 40% of a summer power bill.

SymptomLikely causeWhat to do
Runs, but the air isn’t coldWrong mode or set temperatureChoose cool mode; lower the set temperature
Weak airflow, mild coolingClogged filter or closed ventsClean the filter; open the vents
Poor cooling on hot daysOutdoor unit blocked by leaves or debrisClear the space around it
Warm air from the startLow refrigerant or a compressor faultCall a licensed technician

What Can You Check Yourself?

Start with the remote. Is it in cool mode (usually the snowflake) and set below the room’s temperature? The WA Government recommends no lower than 24°C, because every degree below that can add 10% to your energy bill.

Next, the filter. Daikin’s filter cleaning advice is every two weeks, and swapping a blocked filter for a clean one can cut energy use by 5% to 15%. Here’s how to clean your air conditioner filter on split and ducted systems.

Then head outside. Leaves, plants and garden debris around the outdoor unit make it run less efficiently, so clear them away.

When Do You Need a Technician?

Still warm after those checks? Then it’s probably refrigerant or the compressor. Refrigerant isn’t used up like fuel. According to Fujitsu General’s refrigerant guidance, a low level generally indicates a leak that must be located and repaired, and only a licensed technician should handle it.

That’s why a regas alone rarely lasts: the leak has to be fixed first. WestOz Trades holds refrigerant licence AU45143 and runs 24/7 air conditioning repairs across Perth. Other summer faults are covered in our guide to common air conditioning issues in a Perth heatwave.